第四代HIV诊断试剂检测HIV抗体假阳性原因分析

顾春瑜,刘英丽,王海滨,孙婷婷,何丽婧

武警医学 ›› 2013, Vol. 24 ›› Issue (9) : 758-760.

PDF(568 KB)
PDF(568 KB)
武警医学 ›› 2013, Vol. 24 ›› Issue (9) : 758-760.
论著

第四代HIV诊断试剂检测HIV抗体假阳性原因分析

  • 顾春瑜,刘英丽,王海滨,孙婷婷,何丽婧
作者信息 +

Causes of false-positive results in p24 Ag/anti-HIV combined assay

  • GU Chunyu,LIU Yingli,WANG Haibin,SUN Tingting,and HE Lijing.
Author information +
文章历史 +

摘要

目的分析第四代HIV诊断试剂检测HIV抗体假阳性的原因,减少假阳性检出率。方法选取119例HIV四代试剂检测初筛阳性的标本,送HIV确认实验室确认HIV抗体结果,分析比对两者的结果,探讨出现假阳性的原因。结果119例HIV抗体初筛阳性的标本,送至确认实验室回报结果40例HIV抗体阳性,28例HIV抗体不确定,51例HIV抗体阴性。随着S/CO值的增高,初筛结果与确证结果阳性符合率也随之升高。结论HIV四代检测试剂假阳性率较高,这与试剂同时检测HIV抗体和P24抗原有关。当1<S/CO≤10时,实验室检测人员应依据实验检测结果,结合受检者相应病史和个体状况进行综合分析。

Abstract

Objective To study the causes of false positive results in the fourth generation p24 Ag/anti-HIV combined assay and cut down the false positive results. Methods We picked 119 samples which were reactive in HIV-Ab screening test with the fourth generation HIV assay, then confirmed these samples with West-blot assay and compared them. Results In 119 reactive samples, 40 samples were HIV-1 positive, 28 samples were HIV-Ab indeterminate, and 51 samples were HIV-Ab negative. The higher the S/CO index, the closer the positive results of screening test related to one of confirmatory test. Conclusions The rate of false positive is high with the fourth generation HIV assay, which is relative to the combined detection of anti-HIV-P24. When 1<S/CO≤10, we should consider comprehensive factors such as history of disease, the clinical symptoms, etc.

关键词

HIV抗体 / HIV-1P24抗原 / HIV四代试剂 / 假阳性反应

Key words

antibody to HIV / HIV-1 P24 antigen / the fourth generation HIV assay / false positive reaction

引用本文

导出引用
顾春瑜,刘英丽,王海滨,孙婷婷,何丽婧. 第四代HIV诊断试剂检测HIV抗体假阳性原因分析[J]. 武警医学. 2013, 24(9): 758-760
GU Chunyu,LIU Yingli,WANG Haibin,SUN Tingting,and HE Lijing.. Causes of false-positive results in p24 Ag/anti-HIV combined assay[J]. Medical Journal of the Chinese People Armed Police Forces. 2013, 24(9): 758-760
中图分类号: R446.6   

参考文献

[1] 王 梓,张立红. 第四代与第三代HIV诊断试剂检测结果比较[J].中国误诊学杂志, 2011, 11(3): 257.[2] 中国疾病预防控制中心. 全国艾滋病检测技术规范(2009修订版) [S]. 北京,2009.[3] Aboud S, Urassa W, Lyamuya E, et al. Evaluation of HIV antibody and antigen/antibody combination ELISAs for use in an alternative confirmatory HIV testing strategy in Dares Salaam, Tanzania[J]. J Virol Methods, 2006, 135(2): 192-196. [4] Gurtler L, Muhlbacher A, Michl U, et al. Reduction of the diagnostic window with a new combined p24 antigen and human immunodeficiency virus antibody screening assay[J]. J Virol Methods ,1998, 75(1): 27-38.[5] 颜秀娟,邱昌文,梁进恒,等. 两类ELISA 抗-HIV 试剂对无偿献血者HIV 初筛和确证结果的影响[J]. 广西医学, 2011, 33(3): 370-372.[6] Taegtmeyer M, MacPherson P, Jones K, et al. Programmatic evaluation of combined antigen and antibody test for rapid HIV diagnosis in a community and sexual health clinic screening programme[J]. PLoS One, 2011, 6(11): e28019.[7] 吴 卫,许少侠,黄 媛, 等. 透析患者血清 HBsAg 假阳性伴 HIV 可疑一例分析[J]. 现代检验医学杂志, 2012, 27(4): 76-78.[8] Viani R M, Araneta M R, Spector S A. Parallel rapid HIV testing in pregnant women at Tijuana General Hospital, Baja California, Mexico[J]. AIDS Res Hum Retroviruses, 2013, 29(3): 429-434.[9] 简 练,李雪芽,孙乐栋. HIV 初筛试验假阳性的 SLE 患者 1 例及文献复习[J]. 中国皮肤病学杂志, 2013, 27(1): 100-101.[10] 黎 锋,刘 伟,梁富雄,等.2472例HIV抗体筛查(ELISA) 与免疫印迹试验的比对研究[J].应用预防医学, 2009, 15(5) : 302-304.