慢诱导经口气管插管两种喉镜对血流动力学影响的比较

许喆,王晓林,傅强

武警医学 ›› 2014, Vol. 25 ›› Issue (6) : 591-594.

PDF(779 KB)
PDF(779 KB)
武警医学 ›› 2014, Vol. 25 ›› Issue (6) : 591-594.
论著

慢诱导经口气管插管两种喉镜对血流动力学影响的比较

  • 许喆,王晓林,傅强
作者信息 +

Comparison of effect on hemodynamic response to orotracheal intubation two kinds of laryngoscopes during forgetfulness analgesia slow induction

  • XU Zhe,WANG Xiaolin,and FU Qiang
Author information +
文章历史 +

摘要

目的 比较Airtraq®可视喉镜和Macintosh直接喉镜在慢诱导经口气管插管时的血流动力学反应。方法 选择50例行择期手术的需气管插管的全麻患者,随机分为Airtraq®可视喉镜组(A组)和Macintosh直接喉镜组(M组),每组25例。所有患者均采用慢诱导,口咽部、舌根表面麻醉及环甲膜穿刺后分别使用Airtraq®可视喉镜和Macintosh直接喉镜显露声门行气管插管。观察指标包括麻醉诱导前的基础值(T1)、健忘镇痛慢诱导后3 min(T2)、气管插管前(T3)、气管插管即刻(T4),以及气管插管后1(T5)、3(T6)、5 min(T7)等时间点的收缩压(SBP)、舒张压(DBP)、平均动脉压(MAP)及心率(HR);此外还有声门显露时间、插管总时间及麻醉过程中的不良反应。结果 与T1时间点SBP值(127±15)mmHg相比,仅A组在给药后T2点稍有下降(P<0.05),其余所有数值均较T1无统计学差异; A组SBP值在T2 [(73±9)mmHg]、T3 [(75±8)mmHg]和T5 [(80±13)mmHg]均高于M组,差异有统计学意义(P<0.05);在插管过程中,A组在各时点的MAP、HR与M组比较,差异无统计学意义。A组声门显露时间(8.0±2.2)s较M组(6.1±2.4)s长,但A组的插管总时间(15.9±4.4)s短于M组(19.7±3.8)s,上述差异均具有统计学意义(P<0.05);A组中有1例,M组中有3例轻度的呛咳反应。结论 与Macintosh传统喉镜相比,应用Airtraq®可视喉镜行经口健忘镇痛慢诱导气管插管可减少插管时间,且血流动力学反应无明显差异。

Abstract

Objective To compare the hemodynamic response to orotracheal intubation between using Airtraq® laryngoscope and Macintosh laryngoscope during forgetfulness analgesia slow induction. Methods Fifty patients scheduled for surgery under general anesthesia requiring orotracheal intubation were randomly allocated to undergo intubation using Airtraq® (group A, n=25) or Macintosh (group M, n=25). All subjects were orotracheally intubated after forgetfulness analgesia slow induction, which needed surface anesthesia of pharynx oralis and lingual root. The following data were recorded and analyzed: blood pressure (BP), mean arterial pressure (MAP) and heart rate (HR) before (T1) and after (T2) forgetfulness analgesia slow induction, before (T3) and after (T4) orotracheal intubation and thereafter at 1 (T5), 3 (T6) and 5 min (T7),and glottis exposure time, tracheal intubation time, bucking occurrence. Results In comparison with T1, only the SBP slightly declined after induction in group A [T1 (127?15) mmHg, T2 (116?8) mmHg]. In group A, the DBP at T2 [(73?9) mmHg], T3 [(75?8) mmHg] and T5 [(80?13) mmHg] were higher than those in group M. The MAP and HR during the whole intubation procedure were higher in group A, but had no statistically significant difference. Group A had a long glottis exposure time [group A, (8.0?2.2) s, group M (6.1?2.4) s], but short tracheal intubation time [group A, (15.9?4.4) s, group M (19.7?3.8) s] compared with group M. The amount of bucking occurrence was 1 in group A and 3 in group M. Conclusions In comparison with the Macintosh laryngoscope, tracheal intubation using the Airtraq® laryngoscope has a long glottis exposure time but short tracheal intubation time. And the hemodynamic response to orotracheal intubation between two laryngoscopes has no statistically significant difference during forgetfulness analgesia slow induction.

关键词

Airtraq® / 可视喉镜 / Macintosh直接喉镜 / 慢诱导 / 气管插管 / 血流动力学

Key words

Airtraq® laryngoscope / Macintosh laryngoscope / slow induction / orotracheal intubation / hemodynamic response

引用本文

导出引用
许喆,王晓林,傅强. 慢诱导经口气管插管两种喉镜对血流动力学影响的比较[J]. 武警医学. 2014, 25(6): 591-594
XU Zhe,WANG Xiaolin,and FU Qiang. Comparison of effect on hemodynamic response to orotracheal intubation two kinds of laryngoscopes during forgetfulness analgesia slow induction[J]. Medical Journal of the Chinese People Armed Police Forces. 2014, 25(6): 591-594
中图分类号: R614   

PDF(779 KB)

Accesses

Citation

Detail

段落导航
相关文章

/