荧光静脉留置针的整体设计与研发

杨莉,程艳爽,王瑛,赵洁,姜翠翠,周玉虹,宋海楠,王建荣

武警医学 ›› 2016, Vol. 27 ›› Issue (11) : 1110-1112.

PDF(2933 KB)
PDF(2933 KB)
武警医学 ›› 2016, Vol. 27 ›› Issue (11) : 1110-1112.
论 著

荧光静脉留置针的整体设计与研发

  • 杨莉,程艳爽,王瑛,赵洁,姜翠翠,周玉虹,宋海楠,王建荣
作者信息 +

Overall design and development of fluorescent intravenous catheters

  • YANG Li, CHENG Yanshuang,WANG Ying,ZHAO Jie, JIANG Cuicui, ZHOU Yuhong, SONG Hainan, and WANG Jianrong
Author information +
文章历史 +

摘要

目的 利用荧光粉光致发光的原理,研制一种适合在暗环境下穿刺的荧光静脉留置针。方法 选择发光效率高、无毒、无放射性及组织相容性好的荧光材料及临床应用的留置针,进行整体建模设计,研发荧光静脉留置针的实物产品。结果 完成荧光静脉留置针整体设计,制作了荧光静脉留置针的模型和实物产品。结论 荧光静脉留置针的成功研发为野战环境下的静脉穿刺提供了保障。

Abstract

Objective To develop a novel fluorescent intravenous catheter in order to improve the success rate and save time in low light environments.Methods The fluorescent intravenous catheter was designed with high-efficiency, nontoxic, radiation-free, high-compatibility fluorescent materials and clinically applicable catheters were drafted and modeled. With the assistance of modeling experts, a prototype of the fluorescent intravenous catheter was constructed for the manufacture of the end product.Results Design of the fluorescent intravenous catheter was completed. The model and the end product of the fluorescent intravenous catheter were made available.Conclusions A fluorescent intravenous catheter has been developed.

关键词

荧光 / 留置针 / 设计 / 研发

Key words

fluorescent / intravenous catheters / design development

引用本文

导出引用
杨莉,程艳爽,王瑛,赵洁,姜翠翠,周玉虹,宋海楠,王建荣. 荧光静脉留置针的整体设计与研发[J]. 武警医学. 2016, 27(11): 1110-1112
YANG Li, CHENG Yanshuang,WANG Ying,ZHAO Jie, JIANG Cuicui, ZHOU Yuhong, SONG Hainan, and WANG Jianrong. Overall design and development of fluorescent intravenous catheters[J]. Medical Journal of the Chinese People Armed Police Forces. 2016, 27(11): 1110-1112
中图分类号: R471   

参考文献

[1] 淮 瑾,慕北娜,马如兰.微光下静脉输液的考核方法及操作失败原因分析[J].西北国防医学杂志,2012,33(6):693-694.
[2] Terasaki H,Miyake Y,Awaya S.Fluorescein angiography of peripheral retina and pars plana during vitrectomy for proliferative diabetic retinopathy[J].Am J Ophthalmol,1997,1233:370-376.
[3] 钟旖菱,苏媛媛,何 耀.荧光纳米探针的构建及其在物医学影像中的应用研究[J].东南大学学报,2011,30(1):108-113.
[4] 高鸿雁,陈俊国.医院应急医学救援模块化问题研究[J].中国卫生事业管理,2009(2):95-96,100.
[5] 吴志成.加强灾害救援卫勤保障在平时需把握的问题[J].东南国防医药,2008,10(4):310-311.
[6] 赵文静,赵雪生.灾害医学对护理人员的要求[J].解放军护理杂志, 2004, 21(10):85-86.
[7] 李 静,刘玉莹,刘丽军,等.战时静脉输液穿刺情景模拟演练的设计及效果评价[J].解放军护理杂志,2009,26(5A):75-76.
[8] 左美玉.68例患者急救过程中静脉输液管理[J].内科,2009,4(6):969-970.
[9] 李 静,江雪梅,周丽娟,等.野外暗光静脉输液风险管理的效果分析[J].解放军医药管理杂志,2010,17(10):962-963

基金

国家科技支撑计划项目《汶川地震恢复重建科技快速响应项目-灾区卫生防疫与食品安全研究》子课题《汶川地震人员损伤的特点及医学救治研究》(2008BAK47B08)

PDF(2933 KB)

Accesses

Citation

Detail

段落导航
相关文章

/