中央孔型后房型人工晶状体植入术治疗中高度近视合并散光的临床观察

李欣, 熊瑛

武警医学 ›› 2022, Vol. 33 ›› Issue (10) : 885-888.

PDF(956 KB)
PDF(956 KB)
武警医学 ›› 2022, Vol. 33 ›› Issue (10) : 885-888.
论著

中央孔型后房型人工晶状体植入术治疗中高度近视合并散光的临床观察

  • 李欣, 熊瑛
作者信息 +

Clinical research of the implantation of toric implantable collamer lens-V4c for moderate to high myopia with astigmatism

  • LI Xin, XIONG Ying
Author information +
文章历史 +

摘要

目的 观察散光型中央孔型后房型人工晶状体(TICL-V4c)植入术治疗中高度近视合并散光的临床效果、稳定性及安全性。方法 回顾性研究,收集2018-11至2020-12于北京同仁医院行TICL-V4c植入术治疗中高度近视合并散光患者35例(59眼),分析患者术前及术后1周、1年的视力及屈光度变化,通过散光矢量分析术后散光矫正的有效性和安全性,并观察记录术后并发症。结果 术后1年裸眼视力为0.00(-0.08,0.00),裸眼视力≥1.0的占比88.14%,手术安全指数为1.20(1.00,1.25),有效指数为1.14(1.00,1.20),术后等效球镜明显改善且效果稳定,术后平均散光得到有效且稳定的矫正。散光经CRAVY矢量分析,术后J0得到良好矫正,J45未见明显改变。结论 TICL-V4c治疗中高度近视合并散光有效、稳定且安全。

Abstract

Objective To observe the effectiveness, stability and safety of toric implantable collamer lens with a central hole (TICL-V4c)implantation in the treatment of moderate to high myopia with astigmatism. Methods Thirty-five patients (59 eyes) who had undergone TICL-V4c implantation in Beijing Tongren Hospital from November 2018 to December 2020 were collected, and the preoperative and postoperative visual acuity and dioptric variety at 1 week and 1 year were collected and analyzed. Vector analysis of astigmatism was done to observe the effectiveness and safety of correction of astigmatism by the operation, and to record the postoperative complications. Results The UCVA was 0.00 (-0.08, 0.00) at one year postoperatively, and the proportion of eyes with 1.0 or better UCVA was 88.14%. The safety index was 1.20 (1.00, 1.25),and the efficacy index was 1.14 (1.00, 1.20). The postoperative SE was significantly and stably improved. The postoperative mean astigmatism was effectively and stably corrected. After the operation, J0 was significantly reduced, and J45 had no significant change. Conclusions TICL-V4c implantation is effective, stable and safe for moderate to high myopia with astigmatism.

关键词

散光型中央孔型后房型人工晶状体V4c / 近视 / 散光 / 屈光手术

Key words

toric implantable collamer lens-V4c / myopia / astigmatism / refractive surgery

引用本文

导出引用
李欣, 熊瑛. 中央孔型后房型人工晶状体植入术治疗中高度近视合并散光的临床观察[J]. 武警医学. 2022, 33(10): 885-888
LI Xin, XIONG Ying. Clinical research of the implantation of toric implantable collamer lens-V4c for moderate to high myopia with astigmatism[J]. Medical Journal of the Chinese People Armed Police Forces. 2022, 33(10): 885-888
中图分类号: R778.1   

参考文献

[1] Moshirfar M, Somani A N, Motlagh M N, et al. Comparison of FDA Reported visual and refractive outcomes of the toric ICL lens, smile,and topography-guided LASIK for the correction of myopia and myopic astigmatism[J]. J Refract Surg, 2019, 35:699-706.
[2] Higueras-Esteban A, Ortiz-Gomatiz A, Gutierrez-Ortega R,et al. Intraocular pressure after implantation of the visian implantable collamerlens with centraflow without iridotomy[J].Am J Ophthalmol, 2013,156:800-805.
[3] Huseynova T, Ozaki S, Ishizuka T, et al. Comparative study of 2 types of implantable collamer lenses, 1 with and 1 without a central artificial hole[J].Am J Ophthalmol,2014,157:1136-1143.
[4] Alfonso J F, Lisa C,Fernandez-Vega Cueto L,et al. Clinical outcomes after implantation of a posterior chamber collagen copolymer phakic intraocular lens with a central hole for myopic correction[J].J Cataract Refract Surg, 2013,39:915-921.
[5] Thibos L N, Wheeler W, Horner D. Power vectors: an application of fourier analysis to the description and statistical analysis of refractive error[J].Optom Vis Sci, 1997,74(6):367-375.
[6] Holden B A, Fricke T R, Wilson D A, et al. Global prevalence of myopia and high myopia and temporal trends from 2000 through 2050[J].Ophthalmology, 2016,123(5):1036-1042.
[7] Nakamura T, Isogai N, Kojima T,et al. Posterior chamber phakic intraocular lens implantation for the correction of myopia and myopic astigmatism: A retrospective 10-year follow-up study[J].Am J Ophthalmol, 2019,206:1-10.
[8] Lens C. United states food and drug administration clinical trial of the implantable collamer lens (ICL) for moderate to high myopia[J].Ophthalmol, 2004, 6(1):38-40.
[9] Tomás M, Jaime J, Robert M,et al. Implantable collamer lens for myopia: assessment 12 years after implantation[J].J Refract Surg,2015, 31(8):548-556.
[10] Fernández-Vega-Cueto L, Lisa C, Esteve-Taboada J J, et al. Implantable collamer lens with central hole:3-year follow-up[J].Clin Ophthalmol, 2018,12:2015-2029.
[11] Packer M. The implantable collamer lens with a central port: review of the literature[J].Clin Ophthalmol, 2018,12:2427-2438.
[12] ChenX, Guo L, Han T,et al. Contralateral eye comparison of the long-term visual quality and stability between implantable collamer lens and laser refractive surgery for myopia[J].Acta Ophthalmol, 2019, 97:e471-e478.
[13] Tang Y. Phakic posterior chamber intraocular lens with a central hole in treating patients with moderate to high myopia: a meta-analysis[J].J Ophthalmol,2019, 2019:9496326.
[14] Sanders D R, Schneider D, Martin R,et al. Toric implantable collamer lens for moderate to high myopic astigmatism[J].Ophthalmol, 2007,114(1):54-61.
[15] Leyland M, Zinicola E, Bloom P, et al. Prospective evaluation of a plate haptic toric intraocular lens[J].Eye(Lond), 2001,15(Pt 2):202-205.

PDF(956 KB)

Accesses

Citation

Detail

段落导航
相关文章

/